100 filter selection table choose the family fn xxx with the required current rating and features, and add /?? to determine input/output (line/load) connection style. example: fn 332-6/01 is a 6a filter with solder lug connections. 1 (1.2) 3 (3.6) 6 (7.3) 10 (12) current ratings at 40c (25) a fn 332 -1 /?? fn 332 -3 /?? fn 332 -6 /?? fn 332 -10 /?? family /01 /01 /01 /01 /05 /05 /05 /05 connections g1 g1 g1 g1 housing 10 2 0.8 0.5 inductance l mh 15 2.2 15 2.2 capacitance cx cy nf nf 1200 26 surge energy current absorption aj 2000 1700 2000 350 filter type 190 190 maximum leakage a/phase 250 50/60 250 50/60 maximum operating voltage vac hz hipot test voltage pn e p n vac vdc operating frequency hz dc to 400 dc to 400 mtbf at 40c, 230v, per mil-hb-217f: 710,000 hours. additional specifications approvals 65 65 65 70 weight g standard types fn 332z types (surge protected) fn 332 ? 1 to 10a current ratings ? compact housing with solder or fast-on connections ? optional surge voltage protection (z types) ? nennstr?me von 1 bis 10a ? kompaktgeh?use mit l?tfahnen oder steckzungen ? optionaler sto?spannungsschutz (z-typen) ? courants de service de 1 10a ? bo?tier compact avec connexions par cosses souder ou fast-on ? protection contre les surtensions (types z) performance filter en 133?200 iec 60939 by june 2005 www..net
101 fn 332 insertion loss per cispr 17; a = 50 /50 sym, b = 50 /50 asym, c = 0.1 /100 sym, d = 100 /0.1 sym 1 amp types 10 amp types 3 amp types 6 amp types electrical schematics b d a c 10k 100k 1m 10m -20 -10 0 10 20 30 40 50 60 70 db 10k 100k 1m 10m -20 -10 0 10 20 30 40 50 60 70 db b d a c 10k 100k 1m 10m -20 -10 0 10 20 30 40 50 60 70 db b d a c 10k 100k 1m 10m -20 -10 0 10 20 30 40 50 60 70 db b d a c n 2xl cx fn 332 line load 2xcy p n' e' p' n 2xl cx z fn 332z line load 2xcy p n' e' p' see tables for component values. front view top view l j k c m n b a f d a b c d f j k l m n 45 41 24.8 29 37 12.5 9.6 18.7 3.5 3.9 0.5 0.5 0.5 0.5 0.4 0.2 0.2 0.5 0.1 0.1 tol. mm mechanical data all dimensions in mm; 1 inch = 25.4 mm note: the p and n connections of fn 332 are located in a horizontal position like shown on the picture. the mechanical drawing is a ty pical filter drawing.
|